Glossary · Wiring, circuits and faults

Key points

  • BS 7671 permits an unfused spur off a 30 A or 32 A ring final circuit to be wired in cable as small as 2.5 mm², according to NICEIC.
  • The circuit's protective device cannot protect a spur cable against overload, so a spur should feed only a limited load.
  • NICEIC says overload is unlikely where a spur feeds one single or twin socket, or fixed equipment or sockets through a fused connection unit.
  • Adding a spur changes the circuit and is work for a registered electrician.
  • A spur is not the same as an extension lead. Extension leads add load at the plug, not in the wiring.

How a spur works

A spur, which NICEIC also calls a cable branch, is a length of cable taken off an existing circuit to feed something extra.[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable? On a ring final circuit, each socket normally sits in the loop with a cable on each side. A spur leaves the loop and stops at its own outlet.

A fused spur adds a fused connection unit between the circuit and the load. The unit holds its own fuse, which protects the spur cable and what it feeds. NICEIC describes spurs that feed fixed equipment, or sockets, supplied through a fused connection unit.[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?

An unfused spur has no such unit. It relies entirely on the protective device at the consumer unit, which is the 30 A or 32 A breaker or fuse protecting the whole ring.[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?

Why spurs are limited

The ring’s protective device is much larger than the spur cable can carry for long. NICEIC explains that the current-carrying capacity of 2.5 mm² cable is generally less than the 30 A or 32 A rating of the device at the origin of the ring, so that device cannot protect the spur conductors against overload. If spur conductors were overloaded, the insulation, sheath, surroundings or accessories could be damaged by the temperature rising above rated value.[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?

BS 7671 gets round this by relying on the spur not being overloaded for long periods. NICEIC says the live conductors of a spur are not likely to carry overload current where the spur feeds only:[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?

  • one single or one twin socket-outlet
  • one or more items of fixed equipment supplied through a fused connection unit
  • one or more socket-outlets supplied through a fused connection unit.

Short-circuit and earth-fault protection still apply. NICEIC explains that any of the 30 A or 32 A devices listed for a ring will protect a 2.5 mm² spur against short-circuit current, and will protect the typically 1.5 mm² protective conductor in a flat twin and earth cable provided the earth fault loop impedance at the spur is within the maximum value required for a 0.4 second disconnection time.[1]NICEIC, Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?

The ring itself carries a related condition. Its cable must have a current-carrying capacity of at least 20 A after corrections and the load must be unlikely to exceed it for long.[2]NICEIC, Overcurrent protection - overload

Example

Lena in Roundhay wants an extra socket in her utility room. Her electrician identifies the nearest ring circuit and tests it first. Because the new socket will feed only a washing machine and a spare outlet, he adds a spur to a single twin socket, tests the circuit again and issues a certificate. Lena does not carry out any of the connection work herself.

For a heavier load, the electrician would first assess whether a spur is suitable at all. That choice is a design decision, not a standard answer.

What people get wrong

Many people think a spur is a free way to add as many sockets as they like. NICEIC’s article shows the reverse: a spur is acceptable because it feeds a limited load, and the ring’s protective device cannot protect the spur cable against overload.

Another mistake is adding a spur to a ring that has not been tested. The IET warns that if ring final circuits are added to or altered incorrectly, a dangerous situation could occur with overloaded cables.[3]IET, Back to the Forum - The ring final circuit Testing before and after is part of doing it properly.

The bottom line

A spur is a branch off a ring or radial circuit. A fused spur adds a fused connection unit, and an unfused spur depends on the circuit’s own protective device. Spurs are acceptable only for limited loads, and the ring or radial itself must stay within its rating. Ask a registered electrician to add or alter one.

Common questions

What is the difference between a spur and a fused spur?

A spur is any branch cable taken off a ring or radial circuit. A fused spur is a spur that passes through a fused connection unit, which has its own fuse. NICEIC refers to supplying fixed equipment or sockets via a fused connection unit.

How many sockets can a spur feed?

NICEIC says overload of the spur is unlikely where it feeds one single or twin socket-outlet, or fixed equipment or sockets via a fused connection unit. Anything beyond that is a design decision for a registered electrician.

Can I add a spur myself?

No. Adding a spur means working on a live circuit's wiring, and the load and protection must be assessed. This is work for a registered electrician, who can also test the circuit afterwards.

Is a spur the same as a socket on a ring?

No. A socket on a ring final circuit is connected to two cables, one each side. A spur is a branch from the ring that ends at the equipment it feeds.

Sources

We cite the original source for every fact: legislation, GOV.UK, HSE, the IET, registration bodies and manufacturers' own documents. Each one shows the date we last checked it.

  1. NICEIC. Why can an unfused spur be taken off a ring final circuit wired in 2.5 mm² cable?. Checked 11 November 2026. ↩
  2. NICEIC. Overcurrent protection - overload. Checked 11 November 2026. ↩
  3. IET. Back to the Forum - The ring final circuit. Checked 11 November 2026. ↩